Setting slicing thickness
CAUTION!
Prior to setting up the device, remove the plug from its socket.
Wait until all parts stop moving and the motor disconnects!
•
To set the cutting thickness, remove the cover and feeder opening. Turn the grooved
caps (B, C) (Fig. 1) on the device's cover. Carefully remove the cover with feeder
opening.
Fig. 1
WARNING! Danger of injury!
The double sickle knife is very sharp.
While setting up the device, be careful so as not to cut fingers or hands on the
knife.
•
Screws holding the spacer are
located at the front.
•
The separator establishes the
thickness of the slices.
•
Remove the screws and adjust the
spacer to set the desired thickness
(Fig. 2):
up → thinner slices;
down → thicker slices.
•
The range of slice thickness can be set from 5–35 mm.
•
After completing adjustments, replace the screws.
•
Replace the device's cover and attach the grooved caps.
•
The device is now ready for use.
Fig. 2
- 25 -