Maintenance

Exchanging the HEPA filter

The HEPA filter should be changed
when the message CHANGE FINE
FILTER flashes in the display.
To ensure the machine operates
correctly, use original Miele HEPA
filters only (classification 13).
It is advisable to have the fine filter
changed whenever the machine is
serviced.
If it needs changing before this:
^ Remove the service panel from the
control unit.
^ Loosen the top securing screws on
the coarse filter housing and swing it
upwards.
^ Remove the coarse filter housing.
48
^ Pull the HEPA filter out of it holder
and replace it with a new one.
^ Replace the coarse filter housing and
swing the securing screws back
downwards.
^ Tighten the securing screws.
^ Refit the service panel.
After the HEPA filter has been changed,
reset the operating hours counter to
zero, as follows:
^ Select the Programme CHANGE TA
FINE (see Operation: B - Free
programme selection).
^ Press the Start button 6.
When the service programme has
ended, a message will appear in the
display.
^ To üCONTINUE< press 6.