Thermal cut-out

This machine has a resettable heater
limiter which will shut off the heating
elements in the event of over-heating.
This could be caused, for example, by
large articles covering the heating
elements or if the filters in the wash
cabinet are blocked.
If the message "Check wash cabinet
heating" appears (water has not heated
up in the wash cabinet and the
programme is taking too long), proceed
as follows:
^ Remove the cause of the fault.
^ Take off the service panel.
^ Press the reset button on the heater
limiter located on the right-hand side
of the plinth.
If this switch trips again contact the
Miele Service Department.