450kHz
W : –93.0dBm
N : –91.0dBm
CF1
W/N
/CF2
0.34Vrms
IC301
IC251
9
11
vel meter.
12dB SINAD.)
To make measurements in the AF section, connect the AC level meter.
(ANT input : –53dBm, 1kHz FM, 3kHz DEV (Wide)/1.5kHz DEV (Narrow))
The AF output level is adjusted for a 0.45V/4Ω by the front panel AF VOL control.
TX-RX Unit (VCO)
–5dBm
Q406
Q410
To make measurements in the RF section, connect the RF Wattmeter (50Ω).
LEVEL DIAGRAM
W/N
W/N
0.33Vrms
0.27Vrms
IC251
IC251
8
12
14
3
1
TX-RX Unit
0dBm
7dBm
D409
Q500
Q411
Audio Frequency
W/N
W/N
0.31Vrms
0.33Vrms
IC251
Q251
12
5
7
11.5dBm
21dBm
Q501
Q502
TK-8102
W/N
W/N
W/N
10mVrms
0.55Vrms
0.45Vrms
IC161
IC252
11
10
1
J1
Power
Module
TX-RX Unit
17dBm
25W
IC502
D602
ANT