Kenwood TK-8102 Service Manual page 36

Hide thumbs Also See for TK-8102:
Table of Contents

Advertisement

TK-8102
Item
5. DQT
1) CH : TX low (Wide)
balance
CH : TX center (Wide/Narrow)
CH : TX high (Wide)
2) Transmit
6. MAX
1) CH : TX low (Wide)
balance
CH : TX center (Wide/Narrow)
CH : TX high (Wide)
2) AG : 1kHz/50mV
3) Transmit
7. MIC
1) CH : TX center (Wide/Narrow)
sensitivity 2) AG : 1kHz/5mV
3) Transmit
8. DQT
1) CH : TX low (Wide)
deviation
CH : TX center (Wide/Narrow)
CH : TX high (Wide)
2) Transmit
9. QT
1) CH : TX low (Wide)
deviation
CH : TX center (Wide/Narrow)
CH : TX high (Wide)
2) Transmit
10. DTMF
1) CH : TX center (Wide/Narrow)
deviation
2) Transmit
36
ADJUSTMENT
Condition
Test equipment
Modulation analyzer ANT
or Linear detector
(LPF : 3kHz)
Oscilloscope
Modulation analyzer ANT
or Linear detector
(LPF : 15kHz)
Oscilloscope
AG
AF V.M
Modulation analyzer
or Linear detector
(LPF : 3kHz)
Oscilloscope
Measurement
Terminal
Parts
PC key
MIC
Adjustment
Specifications/
Method
Adjust the waveform as below
± 4.0kHz (Wide)
± 50Hz
± 2.0kHz (Narrow)
According to the large +, –
± 3kHz± 0.2kHz
Check
(Wide)
± 1.5kHz± 0.1kHz
(Narrow)
± 0.75kHz (Wide)
± 0.05kHz
± 0.35kHz (Narrow)
± 0.75kHz (Wide)
± 0.05kHz
± 0.35kHz (Narrow)
± 3.0kHz (Wide)
± 0.2kHz
± 1.5kHz (Narrow)
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents