Kenwood TK-8102 Service Manual page 34

Hide thumbs Also See for TK-8102:
Table of Contents

Advertisement

TK-8102
Test Frequency (MHz)
Channel
TX
1 : Center
470.100
2 : Low
450.100
3 : High
489.900
4
470.000
5
470.200
6
470.400
PCB Section
Item
1. Setting
1) Power supply voltage
DC Power supply terminal : 13.6V
2. VCO lock
1) CH : TX high
voltage
2) CH : RX high
3) CH : TX low
4) CH : RX low
3. IF coil
1) CH : RX center (Wide)
2) SSG output : –53dBm (501µV)
Mod : 1kHz
Dev : 3kHz
4. RF
1) CH : RX center (Wide)
bandpass
CH : RX low (Wide)
filter
CH : RX high (Wide)
2) Track generator output : –30dBm
Connect the spectrum analyzer
to BPF terminal
M
34
ADJUSTMENT
M
RX
TX
470.050
502.600
450.050
485.100
489.950
519.900
470.000
498.500
470.200
498.700
470.400
498.900
Condition
Test equipment
Digital voltmeter
SSG
Digital voltmeter
Track generator
Spectrum analyzer
M2
RX
TX
502.550
415.100
485.050
400.100
519.950
429.900
498.500
415.000
498.700
415.200
498.900
415.400
Measurement
Terminal
Parts
CV
TC402
TC401
AFV
L301
ANT
TC352
BPF
TC353
M2
Fig. 1
M3
RX
415.050
400.050
429.950
415.000
415.200
415.400
Adjustment
Specifications/
Method
± 0.1V
5.5V
± 0.1V
5.5V
Check
0.7V or more
3.25~3.35V (DC)
Adjust the BPF waveform
to Fig. 1
M3
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents