PIPING INSULATION

Liquid and suction lines must be insulated
separately. In a cooling only type air
conditioner, both pipes become cold during
operation. This can cause moisture to
condense on the surface of the pipes,
resulting in heat loss.
PRECAUTIONS WHEN BENDING
PIPES
The air conditioner's performance
will suffer if the piping is crushed.
Bend pipes using the pads of your
thumbs to prevent them from
collapsing (See picture on the right.)
Use a pipe bending tool to bend pipe
wider than 1/2" in diameter.
FLARE FITTING CONNECTION.
(a)
DRY: Never allow any water to get
inside the piping.
There are 3 piping rules:
Cap
Keep cap attached until immediately
before making piping connections.
Insulation
Narrow Pipe
Wide Pipe
Separate insulation is essential
Bend with pads of thumbs
Pipe bending tool
(b)
CLEAN: Never allow dirt, sand or other
foreign particles to get inside the piping.
Keep cap attached until immediately
before making piping connections.
Common insulation
b/a = 0.7 or more
Cap