Appendix A. Possible Errors; Appendix B. Interface Connector Pin Assignment - Promag TR515 User Manual

Time recorder
Table of Contents

Advertisement

Appendix A. Possible Errors

This Section lists all possible error messages that may be generated during the
TR515's normal operation. The table below does not apply to the Test and FMM
modes of the TR515 (see Sections 5 and 6 respectively for complete details on
errors generated in these modes).
LED

Appendix B. Interface connector pin assignment

1
8
TR515 User's Manual
Error
ID-card read error. Read the card again
Read
error
The database is full and new record cannot be
Database
added.
full
Incorrect setting value. Reinitialize the TR515 by
Error 4
issuing the R-command
The database is corrupted. First, try to power the
Error 5
TR515 off and back on again. If this doesn't help,
initialize the database using the E-command or
recover the database using the M-command
Time/date is not set. Use the S-command to
Error 6
correct the problem or reinitialize the TR515 using
the R-command
Ethernet
#1
TX+
#2
TX-
#3
RX+
#4
#5
#6
RX-
#7
#8
25
Description/ Remedy
Wireless/RS-232/RS-485
RS232, TX (PC output)
RS232, RX (PC input)
RS485, (+)
Ground
RS485, (-)

Hide quick links: