Registers - Promag TR515 User Manual

Time recorder
Table of Contents

Advertisement

operation in the Test mode are provided in Section 6. Note, that Test mode
destroys database memory contents in such a way that the data cannot be
recovered even with the M-command.
.

4. Registers

The TR515 features a number of programmable "registers". Basically,
registers are the TR515's functioning parameters (Settings). Registers can be
written to using the C-command, and read from using the B-command (see
Section 3 for details).
Table below lists all available registers:
00H
01H
02H-21H
22H-41H
42H
LED display mode (register 00)
Set
Command
C00,MM
Reply
A
Get
Command
B00
Reply
AMMcc
MM- display mode (00: wall-mount operation, 01: desktop operation), cc-
checksum
This register is used to set the LED display mode. Because TR515 can be
used both as a wall-mount and as a desktop device, the LED data must be
displayed in either orientation. Setting register to 00 (default) adjusts LED
picture for wall-mount operation. Setting the register to 01 rotates the image so
that it appears correctly when operating as a desktop device. Note: the mode
TR515 User's Manual
LED display mode (0: wall-mount, 1:desktop)
Bell duration in seconds (00H-FFH)
Bell table, times (total of 32 registers)
Bell table, enable/disable (total of 32 registers)
Event selection mode, free (IN or OUT)/IN only/OUT only
Possible error codes: 04, 07
Possible error codes: 04, 07
16

Hide quick links: