Summary of Contents for Promag TR515

  • Page 1 TR515 Time Recorder V1.00...
  • Page 2: Table Of Contents

    The Normal mode is entered by powering the TR515 up while not pressing the IN button. Switching the TR515 on while holding the IN button or both IN and OUT buttons down forces the unit into the FMM. The FMM mode of operation cannot be exited other than by switching the TR515 off and back on again.
  • Page 3: Installing The Tr515

    (see Section 4). 1. RS-232/485 Interface Versions The TR515 supports two different interfaces: RS232 for single-terminal communications, and RS485 for multi-terminal communications. Only one TR515 can be attached to the PC’s serial port using the RS232 interface. Up to units interconnected using...
  • Page 4 Green wires cannot be switched. It is recommended that you keep the length of each “bus stem” (i.e. the cable that is used to attach a certain TR515 to the bus) as short as possible, ideally under 10 cm (see the drawing below).
  • Page 5 Most Ethernet installations require cables of substantial and variable length, so you will probably need to make your own cables. For testing purposes PROMAG supplies two kinds of Ethernet cables: device-to-hub (WAS-1499) for connections through a standard Ethernet hub, and device-to-device (WAS-1498) for connections without a hub (i.e.
  • Page 6 BELL CONNECTOR POWER JACK TR515 CONNECTOR AND STATUS TR515EX’s interface connector pin assignment can be found in Appendix B. 3. Wireless Interface Versions The TR515WX designed to operate in the 433MHz ISM (Industrial, Scientific and Medical) frequency band. It features Frequency Shift Keying (FSK) modulation and demodulation capability.
  • Page 7 For multi-terminal RS485 communications, you’ll need to assign a unique (and non-zero!) machine number to each Terminal on the network. Assigning machine numbers The TR515 offers a fast and convenient way of assigning machine numbers in the range from 0 to 10. To assign a new machine number: •...
  • Page 8 Note: machine number is displayed briefly at the Terminal power-up (even if you don’t push the OUT button). Bell relay The TR515 features a built-in bell relay. The relay is capable of controlling a low-power external bell. A daily bell schedule of up to 32 different bell times can be defined.
  • Page 9: Using The Tr515

    For the machine orientation shown on figure of page 3, magnetic (barcode) stripe of the ID-card must face downwards. Note: the TR515 can be programmed to fix event selection to IN or OUT only- in this case event selection won’t work! The last four digits of the ID-cards ID-code are displayed on the LED when the ID-card is read.
  • Page 10: Communications Protocol

    The TR515 communications protocol is based on the GNET protocol specification. Communications parameters are 19200-8-N-1. Communications between the TR515 and the PC takes place in the form of commands sent by the PC and replies from the TR515. Commands and replies are packets of data.
  • Page 11 TR515 User’s Manual Table below lists all possible error codes: Illegal (invalid) command (command code or data is wrong) Record number is out of range (requested record doesn’t exist) Command failed (hardware problem or invalid internal data) Summarized below are all supported commands. Command characters are found in the “CC”...
  • Page 12 NN is a machine (terminal) number in Hex form (00H-FFH), 00H is a “universal” number (see below for details). ‘D’ is a special command. It is used to select a particular TR515 terminal. All terminals power up in a “deselected” state. Each terminal ignores all incoming commands until it receives the D-command whose machine number is either equal to the machine number of this terminal, or 00.
  • Page 13 Possible error codes: 04, 07 Command SYYYYMMDDhhmmss Reply YYYY-year, MM- month, DD-date, hh-hour, mm-minutes, ss- seconds This command is used to set the TR515’s internal clock. Date/time supplied must be valid. Incorrect data (like 31 of February) will be rejected (error 04).
  • Page 14 Get date/time (‘T’, 54H) Possible error codes: 07 Command Reply AYYYYMMDDhhmmss YYYY-year, MM- month, DD-date, hh-hour, mm-minutes, ss- seconds This command is used to get the TR515’s current date and time. Get firmware version (‘V’, 56H) Possible error codes: none Command Reply Aversion_string Version_string length is guaranteed to not exceed 61 character, all character codes are guaranteed to be in the 20H…7FH range...
  • Page 15 Reply RR- register number (00H…FFH); reg_data- the data for the register to be This command is used to set one of the TR515 “registers”. Registers are actually functioning parameters (Settings). Complete description of all available registers can be found in Section 4.
  • Page 16 (i.e. which button was pressed), and the date and time of record creation. The TR515 verifies all database records before sending them out to the PC. This is done because the FLASH memory may actually contain a garbage data.
  • Page 17 Perform self-test (‘Z’, 5AH) Possible error codes: none Command Reply This command is never replied to This command is used to force the TR515 into a special Test mode. No reply is issued by the TR515 upon receiving this command. Details of TR515’s...
  • Page 18: Registers

    MM- display mode (00: wall-mount operation, 01: desktop operation), cc- checksum This register is used to set the LED display mode. Because TR515 can be used both as a wall-mount and as a desktop device, the LED data must be displayed in either orientation.
  • Page 19 TR515 User’s Manual parameter must be supplied as a 2-digit number, i.e. “00” or “01”. Supplying just one digit will generate error 04.
  • Page 20 RR- register number in Hex form (02-21H), hh- hour, mm-minutes, cc- checksum The TR515 features a relay that can be used for external bell control. Up to 32 different ring times can be specified for which the bell will be activated. Each bell table entry consists of two fields: time field (set through these 32 registers) and a corresponding enable/disable field (set through registers 22H-41H).
  • Page 21 RR- register number in the Hex form (22H-41H), SS- state (00: disabled, 01: enabled), cc- checksum The TR515 features a relay that can be used for external bell control. Up to 32 different bell times can be specified for which the bell will be activated. Each bell table entry consists of 2 fields: time field (set through registers 02H-21H) and a corresponding enable/disable field (set through these registers).
  • Page 22: Firmware Management Mode

    TR515 User’s Manual This setting defines if the TR515 will allow the User to choose the event (IN or OUT), or event selection will be fixed to IN only or OUT only. Fixing event may be desirable in case several TR515s are used, with some machines installed at the entrance and serving for registering IN events, and some machines installed at the exit and serving for OUT registration only.
  • Page 23 “FLLD” (FLASH Load): • When receiving the file, the TR515 will blink its IN LED (the LED is on while the TR515 is receiving or expecting to receive a block of data from the PC; the LED is off while the TR515 is programming the data received into its internal FLASH memory) •...
  • Page 24 TR515 User’s Manual files must be exactly 64K in size. Make sure you are trying to downloading a correct one FLASH memory failure. This normally indicates a serious internal Err3 malfunction The LED display is turned off after displaying the message for some time.
  • Page 25: Test Mode

    Finally, there is a timeout error that occurs when you start the download but PC doesn’t send any data (or the TR515 cannot receive the data sent by the PC). This happens when you either set communications parameters of the...
  • Page 26 This indicates that the test sequence has been completed successfully. You can still continue testing the buttons and the reader at this point. The TR515 will behave as if in the Normal Mode of operation, but no records will be added to...
  • Page 27: Appendix A. Possible Errors

    This Section lists all possible error messages that may be generated during the TR515’s normal operation. The table below does not apply to the Test and FMM modes of the TR515 (see Sections 5 and 6 respectively for complete details on errors generated in these modes).
  • Page 28: Appendix C. Cable

    TR515 User’s Manual Appendix C. Cable WAS-1436 ( For TR515WX/TR515SX RS-232 ) PIN1 PIN8 WAS-1436 : LENGH - 2000 mm , WIRE - 8P8C / AWG #28 WAS-1436 DB 9P FEMALE PIN COLOR RJ-11 8P8C PIN GRAY ORANGE BLACK GREEN...
  • Page 29 TR515 User’s Manual 3. WAS-1498 ( For TR515EX TO PC ) Side A Side B PIN1 PIN1 PIN8 PIN8 WAS-1498 : LENGH - 1800 mm , CAT.5 4PAIR 24AWG UTP WAS-1498 Side A COLOR Side B WHITE ORANGE WHITE BLUE...
  • Page 30: Appendix D. Specifications

    TR515 User’s Manual Appendix D. Specifications Display: 4 x 7-segment Blue Light LED Magnetic card reader: ISO Track 2, 75 bpi Barcode reader: Visible or IR, numerical Code39 RFID card reader: 125KHz, ASK, 64bits, Manchester encoding RFID reading range, ISO card-sized tag...
  • Page 31: Appendix F. Software Installation

    LAN, please make sure the IP address you set is not in use to avoid duplication.) Click [Change IP] to change the IP address to be used by TR515, and then click [OK]. P.S. The IP address must not be the existing one.
  • Page 32 TR515 User’s Manual 3. Skip it by clicking [OK]. 4. Select IP Address and Click [DS Settings] button. A. Select Routing mode: Slave. B. Set IP Address (When using multiple TR515E or machines, it is recommended to label the IP address on each TR515E or machines).
  • Page 33 TR515 User’s Manual 5. Enable 「Allow [on-the-fly] serial port parameter changes」. This helps TR515E to remote control the serial parameters. 6. Click [OK] to finish TCP/IP configuration. 7. Complete the New IP settings of TR515E and click [OK] to abort.
  • Page 34 TR515 User’s Manual 8. Open the Application Program of TR515. Input the IP address of the on-line TR515 and select Com Port as 「DS100V2」. Then double click 「000-defaul」 to complete the connection with TR515 terminal. PC to TR515 (using cable WAS-1498) 1.
  • Page 35 *Notice for Operation A. ID「000-defaul」can be set to any TR515 on line. However, when there are multiple TR515 on line, the machine ID cannot be 「000」. Each TR515 must have its own ID number other than 「000」. B. [Time Scheduler] will not work when the machine ID is 「000」. It will be enabled when other ID code is selected.
  • Page 36 TR515 User’s Manual b. Select 「000-default」 to assign the new ID. Set ID as 「 001 」 (The correspondent name can be modified at 「 Device Name」)