Promag TR515 User Manual page 21

Time recorder
Table of Contents

Advertisement

Bell table, enable/disable
Set
Command
CRR,SS
Reply
A
Get
BRR
Command
Reply
ASScc
RR- register number in the Hex form (22H-41H), SS- state (00: disabled, 01:
enabled), cc- checksum
The TR515 features a relay that can be used for external bell control. Up to
32 different bell times can be specified for which the bell will be activated. Each
bell table entry consists of 2 fields: time field (set through registers 02H-21H)
and a corresponding enable/disable field (set through these registers).
Example: programming a bell table entry for 12:00:00
First, set the desired time; select a time register that you haven't used yet
(i.e. 05H). Set the time using the following command: "C05,1200". Next, enable
this time through a corresponding enable/disable register. The corresponding
enable/disable register for time register 05H is 25H (time registers start from
02H, enable/disable registers start from 22H, we use the 4
group). Enable command looks like this: "C25,01".
Event selection mode (register 42)
Set
Command
C42,EE
Reply
A
Get
Command
B42
Reply
AEEcc
EE- event selection mode (00: free selection by the User, 01: fix to OUT, 02:
fix to IN), cc- checksum
TR515 User's Manual
19
Possible error codes:04, 07
Possible error codes: 04, 07
th
register of each
Possible error codes: 04, 07