Promag TR515 User Manual page 14

Time recorder
Table of Contents

Advertisement

Get date/time ('T', 54H)
Command
T
Reply
AYYYYMMDDhhmmss
YYYY-year, MM- month, DD-date, hh-hour, mm-minutes, ss- seconds
This command is used to get the TR515's current date and time.
Get firmware version ('V', 56H)
Command
V
Reply
Aversion_string
Version_string length is guaranteed to not exceed 61 character, all
character codes are guaranteed to be in the 20H...7FH range
This command can be used to verify the TR515's internal firmware version.
Although version string can be any ASCII string, the following format is adopted:
"VX.X cc.......c", where "VX.X" is a version number (i.e. "V1.0") and "cc...c"
is a comment string. Comment string is separated from the version number by a
single space character. Version number will never have any spaces in it.
Initialize the terminal ('R', 52H)
Command
R
Reply
A
This command is used to initialize the TR515. Initialization takes place on
the next power-up, not immediately. Upon initialization, all setting values are
restored to their factory defaults. TR515's internal date and time are also
checked and, if contained garbage, initialized to 1999/01/01 and 00:00:00
respectively. The database data is not erased, this must be done using the E-
command.
TR515 User's Manual
12
Possible error codes: 07
Possible error codes: none
Possible error codes: none

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents