Operation Modes And Functions - Vivax ACP-09CH25AERO Service Manual

Rf-design xf-design
Table of Contents

Advertisement

7.4 Operation Modes and Functions

7.4.1 Fan mode.
(1) Outdoor fan and compressor stop.
(2) Temperature setting function is disabled, and no setting temperature is displayed.
(3) Indoor fan can be set to high/med/low/auto.
(4) The louver operates same as in cooling mode.
(5) Auto fan:
High
Medium
Low
7.4.2 Cooling Mode
7.4.2.1 Compressor running rules:
When indoor room temp.T1 is lower than setting value, the compressor and outdoor fan will shut off.
T1
On
Off
7.4.2.2 Outdoor fan running rules:
The On-off outdoor units have single fan speed. The outdoor fan will run following the compressor except
when AC is in evaporator high temp. protection in heating mode ,condenser high temp. protection in
25

Advertisement

Table of Contents
loading