Operation Modes And Functions; Fan Mode - Vivax ACP-09CH25AELI Service Manual

Hide thumbs Also See for ACP-09CH25AELI:
Table of Contents

Advertisement

8.4 Operation Modes and Functions

8.4.1 Fan mode

(1) Outdoor fan and compressor stop.
(2) Temperature setting function is disabled, and no setting temperature is displayed.
(3) Indoor fan can be set to high/med/low/auto.
(4) The louver operates same as in cooling mode.
(5) Auto fan:
For MS9A-24HRDN1-QRC4W, MS9A-24HRDN1-QRC8W:
For other models:
T1-24
27.5
27
25.5
25
6.0
a
5.0
b
4.0
c
2.5
d
1.0
e
High
Medium
Low
H
(H-L)*0.75+L
(H-L)*0.5+L
(H-L)*0.25+L
L
32