Airflow Data - Maytag iQ Drive R6GI Installation Instructions Manual

Multi-stage, variable speed, inverter driven system with gas heating / electric cooling
Table of Contents

Advertisement

Heating Input
Model Number
(btuh)
80,000
E24K080X
52,000
100,000
E36K100X
65,000
120,000
E48K120X
78,000
120,000
E60K120X
78,000
NOTE: CFM and Rise are independent of ESP in a variable speed blower.
Table 12. Nominal Heating Airflow Rates & Temperature Rises (° F)
2 Ton CFM Settings
Cooling blower
Recommended
Selector Setting
Airflow
(High CFM)
(1) 5
6
7
8
0
0
0
0
0
650
0
0
0
0
1
680
0
0
0
1
0
710
0
0
0
1
1
740
0
0
1
0
0
770
2
0
0
1
0
1
800
TON
0
0
1
1
0
830
0
0
1
1
1
860
0
1
0
0
0
890
0
1
0
0
1
920
0
1
0
1
0
950
0
1
0
1
1
980
0
1
1
0
0
1010
0
1
1
0
1
1040
0
1
1
1
0
1070
0
1
1
1
1
1100
NOTES: Dip switch positions - 0 = OFF 1 = ON
1. Switch (1) selects blower program in conjunction with motor horsepower. 0 = 2 or 4 Ton, 1 = 3 or 5 Ton.
2. Recommended CFM's (factory settings) are highlighted in bold.
2 Ton CFM Settings
Heating
blower
Low Heat High Heat
Selector
Setting
64,800
80,000
(1) 2
3
4 CFM Rise CFM Rise (1) 2
0
0
0
0
800
50
1025
0
0
0
1
850
48
1075
0
0
1
0
875
46
1125
0
0
1
1
925
44
1175
0
1
0
0
950
42
1225
0
1
0
1 1000
40
1275
0
1
1
0 1025
39
1325
0
1
1
1 1050
38
1375
1. Switch (1) selects blower program in conjunction with motor horsepower. 0 = 2 or 4 Ton, 1 = 3 or 5 Ton.
2. Recommended CFM's (Factory settings) and temperature rises are highlighted in bold. Use of any other setting may result in nuisance trips.
3. Temperature rises in tables are approximate. Actual temperature rises may vary.
Table 14. Airflow Settings (CFM) & Rise (° F) for Heating Mode

AIRFLOW DATA

Heating Output
(btuh)
64,800
42,100
81,000
52,650
97,200
63,180
97,200
63,180
3 Ton CFM Settings
Cooling blower
Recommended
Selector Setting
Airflow
(High CFM)
(1) 5
6
7
8
1
0
0
0
0
1
0
0
0
1
1
0
0
1
0
1
0
0
1
1
1
0
1
0
0
1
0
1
0
1
1
0
1
1
0
1
0
1
1
1
3
1
1
0
0
0
TON
1
1
0
0
1
1
1
0
1
0
1
1
0
1
1
1
1
1
0
0
1
1
1
0
1
1
1
1
1
0
1
1
1
1
1
Table 13. Airflow Settings for Cooling Mode
3 Ton CFM Settings
Heating
blower
Low Heat High Heat
Selector
Setting
81,000
100,000
3
4 CFM Rise CFM Rise (1) 2
59
1
0
0
0
875
56
1150
57
1
0
0
1
925
53
1200
55
1
0
1
0
975
50
1300
53
1
0
1
1 1000
48
1350
51
1
1
0
0 1050
46
1375
49
1
1
0
1 1100
44
1400
47
1
1
1
0 1150
42
1450
45
1
1
1
1 1200
41
1500
Heating
Heating Rise
Range
Range (°F)
1025 - 1375
35-65
800 - 1050
1150 - 1500
40-70
875 - 1200
1550 - 2000
40-70
1200 - 1575
1550 - 2000
40-70
1200 - 1575
4 Ton CFM Settings
Cooling blower
Recommended
Selector Setting
Airflow
(High CFM)
(1) 5
6
7
8
900
0
0
0
0
0
935
0
0
0
0
1
970
0
0
0
1
0
4
1005
0
0
0
1
1
TON
1040
0
0
1
0
0
1075
0
0
1
0
1
1110
0
0
1
1
0
1145
0
0
1
1
1
1180
0
1
0
0
0
1215
0
1
0
0
1
1250
0
1
0
1
0
1285
0
1
0
1
1
1320
0
1
1
0
0
1355
0
1
1
0
1
1390
0
1
1
1
0
1425
0
1
1
1
1
4 Ton CFM Settings
Heating
blower
Low Heat High Heat
Selector
Setting
97,200
3
4 CFM Rise CFM Rise (1) 2
66
0
0
0
0 1200
54
63
0
0
0
1 1250
50
58
0
0
1
0 1300
47
56
0
0
1
1 1375
44
55
0
1
0
0 1450
42
54
0
1
0
1 1475
40
52
0
1
1
0 1525
39
51
0
1
1
1 1575
38
blower
Size
11 X 8
11 X 8
11 X 10
11 X 10
5 Ton CFM Settings
Cooling blower
Recommended
Selector Setting
(1) 5
6
7
8
1375
1
0
0
0
0
1400
1
0
0
0
1
1425
1
0
0
1
0
1450
1
0
0
1
1
1475
1
0
1
0
0
1500
1
0
1
0
1
1525
1
0
1
1
0
1550
1
0
1
1
1
1575
1
1
0
0
0
1600
1
1
0
0
1
1625
1
1
0
1
0
1650
1
1
0
1
1
1675
1
1
1
0
0
1700
1
1
1
0
1
1750
1
1
1
1
0
1800
1
1
1
1
1
5 Ton CFM Settings
Heating
blower
Low Heat High Heat
Selector
Setting
120,000
97,200
3
4 CFM Rise CFM Rise
1550
57
1
0
0
0 1200
1650
54
1
0
0
1 1250
1750
52
1
0
1
0 1300
1800
50
1
0
1
1 1375
1850
48
1
1
0
0 1450
1900
47
1
1
0
1 1475
1950
46
1
1
1
0 1525
2000
45
1
1
1
1 1575
Motor
(HP)
1/2
1/2
1
1
Airflow
(High CFM)
1500
1540
1580
1620
5
1660
TON
1700
1740
1780
1820
1860
1900
1940
1980
2020
2060
2100
120,000
1550 57
54
1650 54
50
47
1750
52
44
1800 50
1850 48
42
1900 47
40
1950 46
39
38
2000 45
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iq drive ppg2gi

Table of Contents