Additional Test Requirements And Messages; System Noise Detected; Unstable Battery Detected; Deep Scan Test - Midtronics EXP-803 Instruction Manual

Battery & electrical diagnostic analyzer
Table of Contents

Advertisement

Chapter 3: Battery Test
Battery Rating Systems
Rating
Description
System
CCA
Cold Cranking Amps (specified
by SAE): The amount of current
a battery can provide at 0 ºF
(–17.8 ºC).
CA
Cranking Amps: The amount of
current a battery can provide at
32°F (0 ºC).
MCA
Marine Cranking Amps: The
amount of current a battery can
provide at 32°F (0 ºC).
JIS
Japanese Industrial Standard:
(shown on a battery as a
combination of numbers and
letters.
DIN (A)
Deutsche Industrie-Norm
SAE (A) European labeling of CCA
IEC (A)
International Electrotechnical
Commission
EN (A)
Europa-Norm
7.
Press  or  to select the BATTERY RATING. Press ENTER.
If you select JIS, the analyzer asks for the JIS part number.
Scroll to the part number. To increase your scrolling speed,
hold the  or  key, or use  or  to move up or down
four part numbers at a time. Press ENTER to continue.
8.
Hold the analyzer two inches above the battery case so
that the IR temperature sensor on the underside of the
tester can approximate the battery temperature. Press
NEXT to continue.
Additional Test
Requirements and Messages
For a more decisive result the analyzer may ask for additional
information or further explore the battery's condition. The
following messages and instructions may appear before the
analyzer displays the results.

System Noise Detected

The analyzer has detected computer, ignition noise, or
parasitic drain, and will attempt to retest. Make sure all vehicle
loads are off, doors are closed, and the ignition is in the off
position. The analyzer will automatically retest when it no
longer detects system noise. If the message reappears:
You may be testing too close to a noise source, such as a
charger or other high-current device. If so, move away and
retest.
If you are unable to find the source of the noise, fully
charge the battery and retest. If the message appears after
recharging, test the battery out of the vehicle.
Disconnect the battery cables and retest.
Midtronics Inc.
7000 Monroe Street
Range
100 to 3000
100 to 3000
100 to 3000
72 numbers
from 26A17
to 245H52
100 to 1000
100 to 3000
100 to 1000
100 to 1700
Willowbrook, IL 60527

Unstable Battery Detected

A battery that is weak or that has just been charged may retain
enough electrical activity to be detected by the analyzer
and will adversely affect the test results. A fully charged
battery should stabilize quickly, after which the analyzer
will automatically retest. Weak batteries should be charged
and retested. If the battery is fully charged, check the clamp
connections.

Deep Scan Test

In some cases the analyzer may need conduct a Deep Scan
Test for a few seconds to determine whether the battery
should be replaced or if it has a chance to be recovered.

Voltage Out of Range

The analyzer has detected two 12-volt batteries connected in
series. Disconnect the batteries and test them individually.

Battery Test Results

IMPORTANT: To print results the tester must be con-
nected to a battery measuring 11.50 to 16.00 volts.
The tester prints the results before displaying the battery
decision with an analysis in a series of screens. The analysis
includes the battery state-of-health (SOH). See the Battery
Decisions table for an explanation of the various possible
battery decisions.
NOTE:
When the option TRACK CALLS is enabled, the
tester writes the results to the data card.
Use  or  to scroll to each screen. To return to the Main
Menu, press END. If you are performing a System Test, press
NEXT to continue with the Starter System Test.
Battery
decision
Measured
voltage
Battery
temperature
12
EXP-803
Measured
CCA
Selected
rating
www.midtronics.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Exp-802

Table of Contents