12
Main Structure
IntelliFlo Installation and User's Guide
MAIN SCREEN
Press MENU button to access menu items
POOL DATA
Address
(page 13)
Water Temp
Pool Volume
PRIMING
Max Priming Flow
(page 14)
Max Priming Time
Sys Priming Time
FILTER
Clean Filter Pressure
(page 16)
Turnovers per Day
Cycles per Day
Start Cycle 1
Stop Cycle 1
Start Cycle 2
Stop Cycle 2
Start Cycle 3
Stop Cycle 3
Start Cycle 4
Stop Cycle 4
Clock
TIME / CONTR
(page 22)
Contrast Level
FEATURES
Features 1
(page 23)
Features 2
Features 3
Features 4
Features 5
Features 6
Features 7
Features 8
Features 9
M.O Flow
EXT. CONTROL
Program 1
(page 29)
Program 2
Program 3
Program 4
BACKWASH
Backwash Flow
(page 33)
Backwash Duration
Rinse Time
VACUUM
Vacuum Flow
(page 35)
Vacuum Duration
(1 - 16) [Note: 1-8 when connected to IntelliTouch]
(68˚ - 104˚ F)
(1 - 1000 Kgal)
(30 - 160 gpm)
(1 - 15 min.)
(0 - 5 min.)
(1 - 50 min.)
(1 - 8 counts)
(1 - 4 counts)
(hr:mm - AM/PM)
(hr:mm - AM/PM)
(hr:mm - AM/PM)
(hr:mm - AM/PM)
(hr:mm - AM/PM)
(hr:mm - AM/PM)
(hr:mm - AM/PM)
(hr:mm - AM/PM)
(hr:min - AM/PM)
(0 - 9)
Set Flow (15 - 130 gpm)
Set Duration (0:01 - 10:00)
Set Flow (15 - 130 gpm)
Set Duration (0:01 - 10:00)
Disable/Enable
Set Flow (15 - 130 gpm)
Set Start Time (hr:mm AM/PM)
Set Stop Time (hr:mm AM/PM)
Disable/Enable
Set Flow (15 - 130 gpm)
Set Start Time (hr:mm AM/PM)
Set Stop Time (hr:mm AM/PM)
Disable/Enable
Set Flow (15 - 130 gpm)
Set Start Time (hr:mm AM/PM)
Set Stop Time (hr:mm AM/PM)
Disable/Enable
Set Flow (15 - 130 gpm)
Set Start Time (hr:mm AM/PM)
Set Stop Time (hr:mm AM/PM)
Disable/Enable
Set Flow (15 - 130 gpm)
Set Start Time (hr:mm AM/PM)
Set Stop Time (hr:mm AM/PM)
Disable/Enable
Set Flow (15 - 130 gpm)
Set Start Time (hr:mm AM/PM)
Set Stop Time (hr:mm AM/PM)
Disable/Enable
Set Flow (15 - 130 gpm)
Set Start Time (hr:mm AM/PM)
Set Stop Time (hr:mm AM/PM)
Disable/Enable
Set Flow (15 - 130 gpm)
Set Run Time (0:01 - 00:59)
Set Interval Time (0:02 - 4:15)
Disable/Enable
Set Flow (15 130 gpm) / Time Delay Stop (hr:mn) (0:00 - 0:10)
Disable/Enable (15 - 130 gpm)
Set Flow (15 130 gpm) / Time Delay Stop (hr:mn) (0:00 - 0:10)
Disable/Enable
Set Flow (15 130 gpm) / Time Delay Stop (hr:mn) (0:00 - 0:10)
Disable/Enable
Set Flow (15 130 gpm) / Time Delay Stop (hr:mn) (0:00 - 0:10)
(15 - 130 gpm)
(0:01 - 1:00)
(0:01 - 1:00)
(15 - 130 gpm)
(0:01 - 10:00)