18
Operation Instructions
Phase 4 - Enrolling Door Controls
Step Description
4.
Once all Door Controls are enrolled onto the network – go back to the
PC application and click 'Secure Network' button.
–this safeguards the systems and secures the network.
4.
Select each Door on the application and configure individual settings such
as Door Name, Timed Actions, Relay Times, Ajar Times, Door Option and
Alarm Options etc.
Timed Actions:
IMPORTANT: A timezone must be selected in 'Timed Actions' for one of the
options: Card and PIN, Any Card, Card or PIN , or PIN only.
If all of these are set to 'inactive' then access will be denied for all cards
and PINs on that Door Control.
Example: To Enable PIN codes only on a Wi-PIN&Prox:
Set the Timed Action "Card or PIN" to "Inactive" and set the Timed
Action "PIN Only" to "All day,Every Day". This will grant access for PIN
codes and deny access for cards and fobs.
Configuring Controller Communications
Step Description
1.
On the "Controller" Tab, set the "Connection - Type" to "Serial"
2.
On the "Settings" tab in the communications section, Select the Serial Port
number from the drop-down list connected to the Controller.
Setting the Controller address
The Controller Address is set by configuring the Dip switches as shown below.
Direct Connect - All OFF
Address 1 - Set SW1 ON
Note: Address 3 - Set SW3 ON only
Restoring Factory Settings
To restore the factory default setting , Set ALL Dip
Switches 1,2,3 & 4 to the ON position and then
power-up the Controller.
Example: All Dip Switches are set to the ON position.
Note: Factory Default settings will be restored after
powering up the controller with All dip-switches ON. The
dip-switches's should then be set to the controller
address as shown above in section "Setting the
controller address"