Network Diagrams
Network Diagrams for Multiple Controllers
RS485 Converter
Connect using RS232-RS485
cable to serial port on PC
Set Baud Rate to 19200
PC Network Connections, when using more
than one GSD Controller.
Daisy chain the PC network A , B , 0V to each controller.
Set an individual address for each controller
between 1 & 3 using the dip switches
(see below )
Controller 1
Controller 2
Address 1 - Set SW1 ON
Address 2 - Set SW2 ON
12V
Controller 1
A
12V - 1
0V - 2
B
B - 3
0V
A - 4
TX
RX
Daisy Chain
each controller
0V
B
A
Controller 2
A
B
0V
TX
RX
Controller 3
Address 3 - Set SW3 ON
Phase 5 - Configuring Users
Step Description
1.
Enable a User by ticking the 'Enabled' box for each User
2.
Assign a Name to the User
3.
Assign a UserGroup from the drop-down menu. The UserGroup will
determine the access levels for this User. Refer to section on page 20
'Configuring Access Levels' for information on User Groups.
4.
Assign a Card , PIN number and enroll FingerPrints for the User. Refer to
section FingerPrint Enrolment on page 21
Click 'save' to transmit these changes to the Controller.
Operation Instructions
19