To select a particular event via SIMATIC PDM:
a) Go to Diagnostics > Condensed Status Setup > Condensed Status Mode
and select Yes to enable Condensed Mode.
b) Go to Diagnostics > Condensed Status.
c) For each event, you can select either the Status or the Diagnosis line, then
choose a Status or Diagnosis option from the associated pull-down menu.
3.7.2. Event Status
Event Status allows you to assign one of the status options listed below, to any
of the events listed in Event Index (3.7.1.). This allows you to tailor a device
response appropriate for your particular process. (Event Status affects
Condensed Status
Event Status Options
Good
Good: maintenance required
Good: maintenance demanded
Uncertain: maintenance demanded
*
Bad: maintenance alarm
Uncertain: process related, no maintenance
Bad: process related, no maintenance
Bad: function check/local override
Good: function check
To assign a status to a particular event via the handheld programmer:
a) Go to Condensed Status Mode (3.6.1.) and select Yes to enable Condensed
Mode.
b) Go to Event Index (3.7.1.) and enter the event index number corresponding
to a particular event.
c) Go to Event Status (3.7.2.) and choose a Status option from the table above.
To assign a status to a particular event via SIMATIC PDM:
a) Go to Level Meter > Diagnostics > Condensed Status Setup, select Yes to
enable Condensed Status Mode.
b) Go to Level Meter > Diagnostics > Condensed Status.
c) Select the Status line for the selected Event, then choose a Status option
from the associated pull-down menu.
1)
Condensed Status
See
7ML19985JF02
SITRANS LR250 (PROFIBUS PA) – INSTRUCTION MANUAL
1)
).
on page 138 for more detail.