Chicago Pneumatic RX 2 Safety And Operating Instructions Manual page 16

Hydraulic breakers
Table of Contents

Advertisement

Safety and operating instructions
Dismounting the working tool:
1. Drive out the spring pin by using a break pin
punch and a hammer. Press the retainer pin out
from the hole at the back upwards until you can
remove it through the hole on the front side.
NOTICE
Dismount the working tool with a
lifting strap to reduce the risk of crushed body
parts. Some working tools are heavy, therefore
lift out the working tool in a safe way.
2. Check that the spring pin is not worn out or
damaged. Change if necessary.
16
Mounting the working tool:
1. Clean and lubricate the bushing plentifully. This
is especially important when mounting a new
working tool.
2. Mount the working tool.
3. Rotate the working tool to spread the grease.
4. Mount the retainer pin, and make sure it remains
in position so it not falls through the boring at
the back.
5. Drive in the spring pin by using a break pin
punch and a hammer, until it is flushed with the
percussion unit.
9800 1050 01f | Original instructions