Viscosity
Viscosity (permitted)
NOTICE
Always use clean oil and filling
equipment.

Pressure adjustment

To ensure that the accumulator and hammer are not
overloaded, a separate pressure relief valve should
be installed, see picture below. It is set at a value of
30 bar over the hammer s maximum operating
pressure. If the carrier s breaker circuit is already
equipped with a pressure limiting valve, no extra
valve is necessary.
P
M

Assembly

WARNING
Falling breaker can cause
injuries
Place the breaker in a safe position where it can
not fall over and cause damage.
14
15-100 cSt
P
T
T
Preparation
1. Place the breaker in a position where it is easy
and safe to mount the adapter plate.
Mounting the adapter plate
2. Place a locking washer pair on each screw.
3. Tighten the screws with an spanner.
4. Always use NORDLOCK™ washers under bolt
and nut (NORDLOCK™ is a registered trademark
of Nord-Lock AB).
5.
Adapter plate
RX 2
RX 3
RX 4
RX 6
RX 8
Connecting the breaker to the carrier
6. Place the breaker in a safe way at installation.
9800 1050 01f | Original instructions
RX 2, 3, 4, 6, 8
Tightening torque
200 Nm
200 Nm
390 Nm
390 Nm
390 Nm