Control System F ault C odes
Error Source
Error Type
ID
Name
ID
21
Primary Up /
11
Down Joystick
12
15
16
17
22
Primary Up /
21
Down Directional
Valves
23
Primary Up /
12
Down Flow Valve
15
17
24
Angle sensor
11
12
15
16
17
31
26
Angle sensor
19
cross check
31
Secondary Up /
11
Down. Joystick
12
15
16
17
Part No. 1269074
Condition
Name
Value at 5V
Function is inoperative.Alarm sounds
indicating a fault.
Value too high
Value too low
Value at 0V
Not calibrated
Fault
Valve is operating outside of limits.
Alarm sounds indicating a fault.
Value too high
Valve is operating outside of limits.
Value too low
Alarm sounds indicating a fault.
Not calibrated
Normal function except threshold for
one or both directions is zero.
Value at 5V
Reduced speed function.
Value too high
Alarm sounds indicating a fault.
Value too low
Value at 0V
Not calibrated
Invalid setup
Initiate 1 -second beep of Alarm
Buzzer and required retract into safe
envelope
Out of range
Reduced speed, required retract into
safe envelope
Value at 5V
Function is inoperative. Alarm sounds
indicating a fault.
Value too high
Value too low
Value at 0V
Not calibrated
S-80 • S-85 • S-80X

Control System Fault Codes

Service and Repair Manual
Solution
Cycle power off, then on
after problem has been
corrected.
Calibrate joystick.
Cycle power off, then on
after problem has been
corrected.
Cycle power off, then on
after problem has been
corrected.
Calibrate valve threshold.
Cycle power off, then on
after problem has been
corrected.
Calibrate angle sensor.
Calibrate angle sensor.
Power up controller with
problem corrected
Cycle power off, then on
after problem has been
corrected.
Calibrate joystick.