7. Tightening torques and lubrication

7.1 Tightening torques

Pos.
Description
Terminal box
166
Screws for terminal box cover
251d
Screws for terminal box top
251e
Screws for terminal box top
284a
Screw for cover over supply terminals
277a
Screws for cover
253
Screws for cable entry block
Terminals for supply conductors
Terminals for motor conductors
268
Terminal for PE conductor
279b
Terminal for varistor
276a
Nuts for busbar
281a
Screws for coil
275a
Screws for rectifier board and inverter board
Screws for inverter and IGBT (step 1/step 2)
264
Screws for modules
Motor
152
Screws for fan cover
178
Screws for terminal box
182
Screws for bearing cover in the drive end
182a
Screws for bearing cover in the non-drive end
185
Screws for bearing end shield in the drive end
185a
Screws for bearing end shield in the non-drive end

7.2 Lubricating intervals and grease

Lubricating intervals, grease quantity and type appear from the motor lubricating plate.
1
2
3
4
Fig. 31 Lubricating plate of MGE-F
Torque [Nm]
4
4
4
4
4
4
2.2
2.2
4
1.5
2.2
4
4
4 / 4
2 - 2.5
8
27
8
27
Pos.
Description
5
1
Bearing, drive end
6
2
Grease type
7
3
Ambient temperature
8
4
Ambient temperature
5
Bearing, non-drive end
6
Quantity of grease
7
Lubricating interval
8
Lubricating interval
30 / 32