LB3202 Colibri
1.
Push section 4 downward gently then firmly pull out the centre section 3.
2.
Clean 2, 3 and 4 of powder residue using warm water and detergent. Do not clean
any parts in a dishwasher as this may cause damage.
It is important to clean the mixing bowl assembly thoroughly in order to
prevent bacteria build up.
Section 5 may be cleaned by rotating then pulling outward to remove. Dry then
reassemble in reverse order.
3.
Continue with the machine door open. Place the yellow service key into the slot at the
top centre of the machine and turn the key 90 degrees clockwise. This will restore
power to the machine.
4.
On the inside of the main door are 2 black buttons, the left button is the rinse button.
Ensure the display reads "Ready for use".
5.
Press the rinse button. This will rinse the mixing bowl, dispensing tubes and the filters
in the coffee brew unit. Repeat the process twice to ensure all parts have been flushed.
6.
Remove the grey drip tray at the front of the machine. It separates into 2 sections for
cleaning by pressing the two release tabs. Do not wash in a dishwasher, this will
damage the tray.
7.
Remove the large rear waste container from behind the drip tray. Empty and clean.
Replace ONLY when the display reads 'Insert tray' This is very important. If inserted
too soon, the machine will not register that it has been emptied and ask again!
8.
Remove yellow service key and store inside the machine, the small storage drawer is
ideal. Close and lock the main door. Store your key safely.
9.
The machine will now self test and heat. Wait for the LCD to show "Ready for use"