Diagnostics
Service Diagnostics and Testing
7. Run all upper oven tests (DDOE305T – cont.)
Run all upper oven tests (DSOE305T – cont.)
Step Test
12
Upper Convection Fan – Low speed
reverse
13
Upper Convection Fan – High speed
reverse
14
Upper Door Switch
15
Upper Oven Lights
16
Upper Door Lock
17
Upper Door Unlock
To end the test, press the "CLEAR" pad.
8. Run all lower oven tests (DSOE305T)
This test is similar to RUN ALL TESTS with the exception that only the lower oven components are tested.
This test will cycle the entire lower oven (double oven models) elements, fans, lights, door interlock
switches, and door lock motors in succession. To enter this test, enter diagnostic mode (see accessing the
diagnostic section, page 18). With the unit in diagnostic mode, press the "DOWN ARROW" pad to scroll
to the RUN ALL LOWER OVEN TESTS and press the "ENTER" Pad. When you have selected this test, the
first screen you will see will be the one shown below.
To begin the test, select either "SET" or "ENTER" pad. Once the test has begun, use the "ENTER" pad,
"UP ARROW", or "DOWN ARROW" pad to cycle through the tests.
The following is a table consisting of all the individual components that can be tested in this program.
To scroll through each test, use the "DOWN ARROW" or "UP ARROW" pad, and then press "SET" or
"ENTER" to run the selected component test.
Step Test
1
Lower Inner Bake Element
2
Lower Outer Bake Element
***If no amperage is read, check STEP 1 (Inner Bake Element). If amperage is read, the plug on the relay
© 2010 Viking Preferred Service
Result
Run convection fan at low speed reverse*
* Oven uses a single direction convection
motor (Same direction as low speed)
Run convection fan at low speed reverse*
* Oven uses a single direction convection
motor (Same direction as low speed)
Check door interlock
Check upper cavity lights
Door lock motor is advanced
Engage door lock to unlock door
Result
SKIP THIS TEST
(Not used on DSOE and DDOE models)
Run bake element***
To Change Test
Enter, Up or Down arrow
Enter, Up or Down arrow
Enter, Up or Down arrow
Enter, Up or Down arrow
Enter, Up or Down arrow
Enter, Up or Down arrow
To Change Test
Enter, Up or Down arrow
Enter, Up or Down arrow
board is reversed.