How To Operate - Takenaka System FS2300DV Instruction Manual

2 mega pixel progressive scan color camera
Table of Contents

Advertisement

(3-4) DVI-D output,HDMI connector
D V I
19
18
External view of HDM I connector
(Viewed from the outside of the cam era)
(Note) Pin 17(+5V) are monitor wiring pins. Do not
use of them for the purpose other than that.
(Note) This camera has DVI-D output. Images may
not displayed when connected to HDMI input.
(Note) Use the 1920×1080 ,60Hz(RB)- conforming
multiscan monitor , otherwise images may not be displayed on the monitor.

4. How to Operate

(4-1) Connection method
● Connection
Refer to the connection example between the camera and peripheral devices (Fig. 4-1).
(1) Remove the cover of the lens attachment section and
attach a lens (separately sold).
(2) Connect the camera to a power supply unit
(separately sold) with a camera cable (separately
sold). The maximum allowable length of a camera
cable is 15 m.
(3) Set the camera operation modes in accordance with
the setting instructions for the operation modes and
the shutter speed that are described in another
section.
(4) When the digital output on the rear panel of the
camera is used, connect the digital output connectors
and the input terminals of the image processing units
(frame grabber board, computer, etc.) with digital
cables (separately sold) conforming to Camera Link.
The maximum allowable length between the digital
output connector of the camera and the input terminal
of said image processing unit is 10m.
(5) When the DVI-D output on the rear panel of the camera is used, connect the DVI-D output connector (HDMI shape) and
the 1920
1080 ,60Hz(RB) -conforming multiscan monitor with the DVI-D - HDMI conversion cable. The maximum
×
allowable length between the DVI-D output connector of the camera and the multiscan monitor is 5m.
(6) Confirm the connecting condition before turning on the power switch of the camera.
In 1 or 2 seconds after the power is turned on, the LED operation indicator on the rear panel of the camera changes
from orange to green to show that the camera is in operation.
(Note) The maximum allowable lengths of the camera cable and the digital cable aforementioned are not for the purpose of
guaranteeing the operation of the camera. Proper image signals may not be obtained even when the cables are
within the allowable ranges, depending on the installation conditions of the camera, types of cables in use and others.
1
2
Pin No.
DVI signal name
1
TMDS DATA 2+
2
TMDS DATA 2 shield
3
TMDS DATA 2-
4
TMDS DATA 1+
5
TMDS DATA 1 shield
6
TMDS DATA 1-
7
TMDS DATA 0+
8
TMDS DATA 0 shield
9
TMDS DATA 0-
10
TMDS DATA CLK+
F C- CAM
FC camera
PU100
or PU120
Pulse generating
circuit
sensor and oth ers
Fig. 4-1 Connection example between camera
- 6 -
Pin No.
DVI signal name
11
TMDS DATA CLK shield
12
TMDS DATA CLK-
13
N.C
14
N.C
15
DDC/SCL
16
DDC/SDA
17
GND (monitor)
18
+5V (monitor)
19
HOT Plug Detect
-
-
1920 × 1080
DVI - HDMI con version cable
Camera Link cable
Camera cable
6P 12G etc.
Capture board
( Camera L ink)
O N
PO W E R
C Y C L
T R I G
L O CK
DI R E C T
P O W E R U N I T
P U 10 0
TRIG
and peripheral devices
N11A27;6/37
Computer

Advertisement

Table of Contents
loading