2. Grip dryer from top and rock back and forth, making sure all four
legs are firmly on floor. Repeat, rocking dryer from side to side.
If dryer rocks, go to Step 3 and adjust leveling legs.
(appearance may vary)
1. Check the electrical requirements. Be sure that you have the
correct electrical supply and the recommended grounding
method. See "Electrical Requirements. "
2. Check that all parts are now installed. If there is an extra part,
go back through the steps.
3. Check that you have all of your tools.
4. Dispose of/recycle all packaging materials.
5. Plug into a grounded outlet, or connect power.
3. If dryer is not level, use a 1" or 25 mm open-end or adjustable
wrench to turn the leveling leg counterclockwise to lower the
dryer or clockwise to raise the dryer. Recheck levelness of dryer
and that all four legs are firmly in contact with the floor. Repeat
as needed.
HELPFUL TIP: You may want to prop up front of dryer about 4"
(102 mm) with a wood block or similar object that will support
weight of dryer.

COMPLETE INSTALLATION

6. Check dryer operation:
Models with Electronic Display:
Close dryer door. Set the cycle. Operating time will accumulate
per number of coins.
Mechanical Models:
Some accumulated time may be on the timer due to factory
testing. Close dryer door. Turn timer-set knob to the right.
(Operating time will accumulate per number of depressions and
type of timing cam used.) Push START button.
Using a full heat cycle (not the air cycle), let the dryer run for at
least five minutes. Dryer will stop when time is used up. Make
sure the dryer turns off.
NOTE: Dryer door must be closed for dryer to operate. When
door is open, dryer stops, but timer continues to run. To restart
dryer, close door and push START button (mechanical models
only).
7. Open the dryer door. Check that the inside of the dryer is warm.
If the burner does not ignite and you can feel no heat inside the
dryer, shut off dryer for five minutes. Check that all supply valve
controls are in "ON" position and that the electrical cord
is plugged in. Repeat five-minute test.
8. If drying time is too long, make sure that the lint screen is clean
and that there are no obstructions to airflow in the dryer vent
system.
9. Restart the dryer and allow it to complete a full heat cycle
(not air cycle) to make sure it is working properly.