Installation and assembly

Distances
The unit should be positioned on a hard, level and horizontal surface. It should be
positioned at least 10 cm at the side and rear from a wall or 15 cm from other
units. Several displays can be butt-mounted horizontally and vertically .
Mounting of unit
With ceiling mounting (VESA adapter / 100 x 100 mm) or installation with the stand,
proceed as follows:
• Hold the display on the VESA adapter or stand, and secure with screws.
• The display may only be aligned in portait format.
Since the screws are extremely significant for the installation, observe the
following:
Number of screws
Thread
Strength
Immersion depth
Torque
Provide adequate ventilation
Ventilation holes are located on the rear of the housing.
Ambient temperature
The ambient temperature must not fall below or exceed the permitted values.
Minimize reflections
The unit should be positioned so that reflections of lights, windows, pieces of
furniture with shiny surfaces or light-colored walls do not appear on the screen.
Minimize mirroring
In order to reduce mirroring on the unit, only use reflected light (non-dazzling) for
the ceiling lighting.
Mirroring can only be eliminated if the screen is clean and free of grease (see
Section 6.2 "Cleaning").
Change of environment
If the unit is brought into a warm environment from a cold one, water may
condense in it. The unit should not be switched on until all the condensed water
has evaporated again, including that inside the unit. This may take several hours,
depending on the conditions.
21" gray scale flat panel display SMD 21300
A5E00185696B-001
4
M4
8.8 to DIN EN ISO 898-1
Min. 8 mm
Max. 12 mm
Max. 3 Nm