Fatal 7102 Offline Cancel Page - Printing Innovation iCUBE 1 User Manual

Icube series
Table of Contents

Advertisement

Fatal 71 02 offline cancelpage
Dongle
Please ensure:
1. That P2002 on the MPCA has not been lifted from the solder pads on the PCA
2. That there is insulating tape on the dongle covering the solder pads
3. That the wires between the dongle PCA and P2002 are connected to the dongle PCA
and to the connector
Incorrect NVM settings Interruptioin the sensor power
How to detect:
gpio_pin_get SNSR_PWR_B_EN
returns 0
How to fix:
gpio_pin_set SNSR_PWR_B_EN 1 ss_home
mech_clear_error
Lift sensor dirty
Clean lift sensor
Service station connection fault
Eject service station, unconnect, connect, home
Clean service station
Replace service station
Service station is in wrong position
How to fix:
maint_enable 0
ss_goto cap
gpio_pin_get
SS_LIFT_UP ss_down
gpio_pin_get
SS_LIFT_UP
maint_enable 1
Explanation:
The state of the lift sensor can be checked by running the following TCL commands after
the engine is fully booted:
1) maint_enable 0 (disables maintenance to prevent the maintenance state machine from
overriding commands to position the maintenance module)
2) ss_goto cap (moves to the capped position and raises the cap)
3) gpio_pin_get SS_LIFT_UP (should return a 1 indicating that cap is lifted and that the sensor
is reading the correct position. Verify that the cap is lifted to the full height; if not then
there is a problem with the lift mechanism. If the cap is lifted, then there is a problem with
the sensor).