Siemens SMD 18101 CS Instruction Manual page 40

18 inch gray scale flat panel display
Table of Contents

Advertisement

Commissioning
7.3 Description of OSD menu
Main menu
7-12
Functions
→ Test pattern
→ Reset to factory defaults
(only applies with PIP setting
= "Off")
Adjustment/range
Off, colorbars, graybars
SMD 18101 CS / SMD 18101 CP / SMD 18101 D
Instruction Manual, 11/2005, A5E00472377A-002
Description /
Fixed test patterns are
available
The test patterns are
generated directly in the
display's processor. The test
patterns can be used to
analyze whether a fault is
present in the control
electronics or has to be
searched for in the
plugs/cables or video source.
1. If the test pattern is
displayed without faults,
one should first check the
connections and video
sources.
2. If the video source and
the connections are OK,
and if the test pattern is
displayed perfectly, the
fault must be searched
for in the video input of
the monitor.
The test patterns can also be
used to check the panel
quality:
Proof of the contrast with
gray scales and color
channels (independent of
picture, picture program,
graphics card and
connectors).
Complete writing of all
pixels on the display
surface (limitation: the
first column on the left of
the panel remains black).
Test of columns or line
driver.
All parameters are reset
The following are deleted:
User settings
Custom settings
The following are reset:
Backlight
Sharpness
User color location
Signal settings
Black level settings
RGB relation
DPMS settings
Language

Advertisement