Commissioning
7.3 Description of OSD menu
Main menu
Servicelevel 2 (S)
7-10
Functions
DPMS
Status
Note
Settings in the following menus may only be carried out by trained servicing personnel!
LUT
→ LUT backlight command
→ Select display function
Calibration
→ Temperature
→ Backlight command
→ Backlight calibrate
→ Backlight
→ ADC Calibration
Adjustment/range
On/off
On/off
A gamma curve from a list of
five curves
Slider from 0 ... 100
SMD 18101 CS / SMD 18101 CP / SMD 18101 D
Instruction Manual, 11/2005, A5E00472377A-002
Description /
The DPMS (Display Power
Management System) can
be switched on/off
The backlight is reduced to a
low basic brightness and the
LC is switched off, if the
DPMS is activated and if no
input signal is connected any
longer. This saves power,
and increases the service life
of the backlight.
The current display settings
in the respective picture
mode can be called here.
Activate change in backlight
value when changing the
gamma curve.
On: the setpoint of the
factory adjustment is used as
the new backlight value
when changing the gamma
curve.
Off: the backlight value is
retained when changing the
gamma curve.
The five gamma curves in
the selection list can be set
individually using SMfit ACT.
The factory calibration is
carried out in this menu. The
currently valid gamma curve
can also be selected here
Specified as info in °C
Facility for reading out the
current tab value of the
backlight
Calibration of backlight
Function and results are
output.
Adjustment of brightness of
display backlight
Adjustment of overall
brightness to ambient
lighting.
Automatically calibrate A/D
converter for the applied
video level

Advertisement