Chapter 4
PC Health Status
This menu shows the hardware monitor configuration
settings. Select an item then press <Enter> to display the
configuration options.
SYS/CPU Temperature
The onboard hardware monitor automatically detects and
displays the CPU and motherboard temperatures.
FAN2 Speed (CPU FAN)
The onboard hardware monitor automatically detects and
displays the CPU fan speeds in rotations per minute (RPM).
If the fan is not connected to the motherboard, it displays
N/A.
CPU Voltage, 3.3V voltage, 5V voltage, VBAT, etc
The onboard hardware monitor automatically detects the
voltage output through the onboard voltage regulators.
Smart Fan Mode Configuration
It allows you to configure the smart fan feature. You
can manually turn on the CPU fan or set the target CPU
temperature at which the CPU fan will start running if the
fan is not yet turned on. And the CPU fan can also be turned
off automatically if the temperature for the CPU is at or
below the specified value. Refer to Motherboard Layout on
Chapter 3 Block Diagram for CPU fan connectors.
Item
Selection
Manual
Manually set the fan speed
Mode
Smart Fan
It presets the target system temperature
Control:
(degree Celcius) at which the system fan will
start running if the fan is not yet turned on
with this mode. And the system fan can also
be turned off automatically if the tempera-
ture for the system is at or below the speci-
fied value.
Temp1/2/3/4: sets the temperature (in
for the each of the following respective fan
speed (in duty cycle)
FanOut T1/T2/T3: sets the fan speed from
scale 1 to 255(full) in duty cycle
Note: The default value is the recommended
settings as it has been tested operational in our
lab.