9.2

AquaLink RS Dual Equipment

AquaLink RS Dual Equipment
(2/6, 2/10, 2/14) Conversion Wiring Diagram
S1 DIP SWITCH SETTINGS
Factory Setting
When Turned
#
OFF
ON
1
Aux1
Cleaner
2
1 SPD Filter Pump
2 SPD Filter Pump
3
Not Used
Not Used
4
Cool Down
Disabled
5
Normal
See Manual
6
Heaters
Shared Heater
7
No Solar
Solar Installed
8
Gas Heater
Heat Pump
S2 DIP SWITCH SETTINGS
Factory Setting
When Turned
#
OFF
ON
Heat Pump Priority
1
Solar Heat Priority
2
Not Used
Not Used
3
Not Used
Not Used
Not Used
4
Not Used
AUTO/SERVICE/TIME OUT Button
Pressing this button switches between the
three (3) modes outlined belo
w.
AUTO
Mode
Normal operation. Leave the system in
this mode unless you are servicing the
pool or the system. Power Center
buttons (above) do not work.
SERVICE
Mode
In-house Controller is locked out.
Allows manual operation of equipment
using the buttons above. This mode will
stay on until the button is pressed again.
TIME OUT
Mode
Allows service person to override all
programs and lock out indoor Controller
for three (3) hours. Any equipment turned on
will remain on, any equipment left off will
remain off. Operation will automatically switch
back to AUTO mode after three (3) hours.
NOTE: Safety Interlocks are not in effect
when service or time mode is active.
IMPORTANT INSTALLATION INSTRUCTIONS:
1. Installation must be by a qualified electrician and must comply with all national, state, and local codes.
2. Power Center must be mounted at least five (5) feet away from the inside edge of the pool.
3. Install to provide drainage of compartments for electrical components.
4. After wiring, install panels over wiring compartments and keep Power Center door closed.
5. For indoor or outdoor use.
For technical information, call Jandy Pool Products, Inc., at 707-776-8200, ext. 260.
CAUTION
Read Installation Manual completely
before installing. This product must
be wired in accordance with the
Installation Manual.
ATTENTION
Lire la notice technique.
Network Connectors
Connect red four-pin connectors
Service Controller
from Controllers or Remotes
Connector
4 3 2 1
4 3 2 1
To Controller
(red terminal bar)
S1
RESET
AUTO
SERVICE
TIME OUT
S2
Relay Sockets (24 VDC output)
System must be in SERVICE or TIME OUT mode for these buttons to operate.
POOL PUMP
Button
Turns the Filter Pump on and off.
SPA PUMP
Button
Turns the Filter Pump on and off.
AUX
Buttons
Turns on and off auxiliary equipment
as labeled. AUX 7 socket is the Spa
Pump Relay Socket.
WARNING
To reduce the risk of injury, do not
permit children to use this product
unless they are closely supervised
at all times. Water temperature in
excess of 100°F/38°C may be
injurious to your health.
Adjustable Fr Sensor
Freeze/Air Solar Sensor
Pool Temp Sensor
6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
To Spa Side
To Sensors and Heater
(brown terminal bar)
(green terminal bar)
JVA Sockets
(24 VAC output)
POOL
and
SPA HEATER
Turns the heater on and off. The switch
on the heater must be on, the heater
thermostat should be turned to max.,
and the filter pump must be running
for heater to fire.
SOLAR
Button
Activates optional JVA (valve actuator)
plugged into the "solar JVA" socket,
and activates optional relay plugged
into the "solar pump" socket.
6000 Condor Drive • Moorpark, CA USA 93021
707.776.8200 • Fax 707.763.7785
Litho in USA © Jandy Pool Products, Inc. 0711
AVERTISSEMENT
Pour réduire le risque de blessures,
ne pas permettre aux enfants d'utiliser ce
produit à moins qu'ils soient supervisés
de près en tout temps. Des températures
de l'eau supérieures à 38°C/100°F peu-
vent présenter un danger pour la santé.
Spa Temp Sensor
Pool Low Voltage Heater
Relay Sockets
(24 VDC output)
Buttons
Sheet #7255, Rev. G