Unit Function - Kärcher HDS Middle series Service Manual

Table of Contents

Advertisement

Unit Function

2.27 Pressure switch function
1
11
1 High-pressure outlet (unpressurised)
2 Pressure gauge (unpressurised)
3 Non-return valve (closed)
4 Rotary knob
5 Overflow valve (closed)
6 Throttle bore
7 Pressure switch, „OFF" (closed)
8 Water inlet
9 Motor protection contacts (K1) (closed)
10 Pump starts up
11 Pressure switch, „ON" (closed)
Page 62 / 127
2
3
10
9
24 volt
2.27.4 Handgun is reopened with unit
As soon as the handgun is opened, the pressure
enclosed between the non-return valve (3) and
the handgun escapes. The pressure switch (11)
closes.
This means the control circuit is closed again,
the motor contactor (9) tightens, closes the
contacts, the motor starts up and the pump builds
up the operating pressure again (see circuit
diagram).
HDS Middle Range / HDS Premium Range
6
8
switched on
Service Manual 04.2008
4
5
7

Hide quick links: