Error Messages With Service Requirement - Kärcher HDS Middle series Service Manual

Table of Contents

Advertisement

Unit Function

2.2.4 Error messages with service requirement

Note
One display is used here for several faults. It may be possible to localise the fault by reading
out the fault memory.
Display
Explanation
Low-water protection sticks
10 short start-ups/leakage
Contactor does not switch
Temperature sensor (NTC) is defective
Flame sensor detects impermissible state
RFID read-write electronics are defective
Page 20 / 127
HDS Middle Range / HDS Premium Range
Note
Check low-water protection.
Remove leaks in the high-
pressure system.
Check contactor.
Check current transformer
installation.
This fault is not saved.
Check NTC
NTC cable chafed bare
Possible causes:
- Fuel solenoid valve
- Fuel line/filter
- External light
- Inspection glass is sooty
- Scale in combustion chamber
- Fuel empty and
Check connection with RFID
read-write electronics.
Service Manual 04.2008
fuel empty signal is defective

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents