Propane Gas - 44,000 BTU input at 10.0 in. W.C.
Units after Serial Number Break (WKGD 481835795)
Propane Gas - 50,000 BTU input at 10.0 in. W.C.
Gas Line Pressures
Natural - Recommend (in. W.C.) 7.0, Min 5.0
Natural - Recommend (in W. C.) 8.0, Min 6.0 for Units
after Serial Number Break (WKGD 481834889)
Natural Gas - 50,000 BTU input at 5.0 in. W.C.
Propane - Recommend (in. W.C.) 11.0, Min 11.0 (All
Propane Units)
Maximum 14.0 in. W.C. (Nat. or Prop.)

TOOLS

Standard
Standard set of hand tools
VOM with ability to measure micro amp current
VOM with minimum of NFPA-70E CAT III 600V,
UL/CSA/TUV listed. Sensitivity of at least 20,000
ohms per volt. Meter leads must also be rated at
CAT III 600V.
Gear Puller to remove blower
Special
Temperature tester (thermocouple type)
Manometer
F32700 Rev. B (0315)
WKG Series Full Size Gas Convection Ovens - GENERAL