Gas Burner - Wolf WKG Series Service Manual

Hide thumbs Also See for WKG Series:
Table of Contents

Advertisement

WKG Series Full Size Gas Convection Ovens - REMOVAL AND REPLACEMENT OF PARTS
Fig. 11
5.
Remove probe by pushing it through the oven
wall and into the control panel area.
Fig. 12
NOTE: The hole in the oven cavity wall does not line
up straight with the oven cavity outer shell, therefore
the probe must be removed at an angle.
6.
Reverse the procedure to install the replacement
probe.
7.
Adjust the temperature control as outlined under
manual data: was removed because it is no
longer valid..

GAS BURNER

electrical power to the machine and
follow lockout / tagout procedures.
SHUT OFF THE GAS BEFORE
SERVICING THE UNIT.
1.
Remove the BOTTOM FRONT COVER.
2.
Disconnect the ignition cable and the flame
sense lead wire.
Disconnect the
Page 11 of 74
Fig. 13
3.
Remove the bolts securing the gas manifold to
the oven and place the manifold to the side.
Fig. 14
4.
Remove the screws securing the burner cover
then lift out.
Fig. 15
5.
Grasp the burner and lift out.
Fig. 16
F32700 Rev. B (0315)