Patton electronics 2720 User Manual page 7

T1/fractional t1 csu/dsu with ethernet bridging
Hide thumbs Also See for 2720:
Table of Contents

Advertisement

Switch S2-6 and S2-7: Clock Mode
Set Switch S2-6 and S2-7 to determine the 2720's transmitter tim-
ing.
S2-6
S2-7
Clock Mode
Off
Off
Network Clock . Transmitter timing is
derived from the received line signal.
On
Off
Internal Clock . Transmitter clock is
derived from an internal oscillator.
NOTE 1: When using the Model 2720 as a high-speed short
range modem, one unit of the link must be configured in Internal
Clock mode, and the opposite end unit must be configured for
Network Clock mode.
If the ERR LED on the front of the unit is flashing (or on) it could
be an indication of a clocking problem. Double check your clock
mode settings and Tx Clock Invert S1-3 settings.
Switch S2-8 Reserved
11
3.1.2 Switch S1
The chart below shows the default configurations for Switch S1. A
description of all S1 options follows this table.
S1 SUMMARY TABE
Position
Function
S1-1
RDL Type
S1-2
Reserved
S1-3
Tx Clock Invert
S1-4
Line Build Out
S1-5
S1-6
Reserved
S1-7
Reserved
S1-8
Reserved
Switch S1-1: RDL Type
Switch S1-1 selects the type of Remote Digital Loopback that the
2720 will initiate when the RDL is initiated from this unit. The 2720
will respond to both the V54 and the CSU loopback regardless of the
setting of S1-1
S1-1
RDL Type
On
Initiate a V.54 RDL loop when selected
Off
Initiate a CSU loopback when selected
Switch S1-2: Reserved
Factory Default
Selected Option
V.54 RDL
On
On
Normal
Off
Off
0dB
Off
Off
Off
Off
12

Advertisement