Table 2: List Of Tools And Service Kit - Aqua Lung MenTOR Technical Manual

Double hose regulator
Table of Contents

Advertisement

Table 2: List of Tools and Service Kits (cont.)
pART # DESCRipTiON
1/4" Nutdriver
N/A
small/medium blade
screwdriver
N/A
bottle brush
2¾" diameter
N/A
7-0543
clamp Installation Tool
7-0550
Nut spanner Tool
N/A
Torque wrench ft/lbs and in/lbs
9-43001
3/4" socket
9-44584
3/4" wrench
N/A
28mm wrench (or 12" adjustable) & socket
9-47436
Phillips screwdriver #2
9-44363
3/8" drive flex handle
N/A
7/32" (5.5mm) wrench
N/A
hex Key (3mm, 4mm, 8mm)
108560
mentor service Kit
pART #
716021
716018
124602
716038
TEST
Leak Test
mP
mP creep
opening effort
AppLiCATiON
second stage disassembly/reassembly/adjusting
various
cleaning inside of corrugated hoses
hose clamps
body retaining nut
To apply torque to inlet fitting, retaining nut and spring retainer
used with nut spanner tool removal/installation
used with nut spanner tool removal/installation
spring retainer
various
socket
hose clamps
Lever assembly, port plugs, adjustable crown, mP adjustment
Table 3: Torque Specifications
DESCRIPTION / KEY ITEM #
spring Retainer (29)
Retaining Nut (23)
Yoke Nut (53)
Lever support screw (36)
Table 4: Bench Test Specifications
CONDiTiON
Inlet 2,500-3,000 (±100) psi
Inlet 2,500-3,000 (±100) psi
Inlet 2,500-3,000 (±100) psi
Inlet 2,500-3,000 (±100) psi,
mP 135±5 psi
TORquE
25±2 ft/lbs
40±2 in/lbs
20±2 ft/lbs
12±2 in/lbs
SpECiFiCATiON
No leaks allowed
135±5 psi
5 psi max between 5 to 15 seconds
after cycling regulator (purge)
±0.7 ±0.2 inch h ² 0