Aqua Lung MenTOR Technical Manual page 14

Double hose regulator
Table of Contents

Advertisement

14
6. Attach the regulator to a charged cylinder with the hose
outlets facing upward. slide the rubber hoses onto the
inhalation and exhalation outlets on the first stage body as
shown in the picture. Install the hose clamps (19) into the
grooves located at the end of the rubber hose.
7. Insert the screw (1) through the clamp holes. Thread the
hex nut (2) onto the screw. while holding the hex nut with a
7/32" (5.5.mm) wrench, tighten the screw with a small blade
screwdriver.
8. Install the mouthpiece (13) onto the mouthpiece body (8).
secure the mouthpiece with a clamp (12). The locking tab
of the tie wrap clamp should be position on the side of the
mouthpiece. Trim the clamp with side cutters.
9. squeeze the mouthpiece together and slide the lip shield
(14) into place.
10. Install the neck strap (15) through the buckles on each
side of the mouthpiece as shown in the picture.
MENTOR Technical Maintenance Manual
11. Attach the regulator to a cylinder with the rubber hoses
coming off the top of the regulator. stand the cylinder upright.
Attach the mouthpiece body to the two hoses with the mouth-
piece facing upward. Tighten the two connectors to the body.
ThiS ENDS REASSEMBLy

Advertisement