Patton electronics 1093 User Manual page 10

High speed baseband modem
Hide thumbs Also See for 1093:
Table of Contents

Advertisement

5.3.4 V.52 BER TEST GENERATOR
The Model 1093 has a built-in test pattern generator and detector.
It can be invoked at both ends of a link simultaneously or it can be
used with the Local Analog or Remote Digital Loopbacks. The follow-
ing example requires two operators: one to initiate and monitor the test
at the local Model 1093, and one at the remote Model 1093. To use
the V.52 BER test by itself, both operators should simultaneously follow
these steps.
1.
Locate the 511/511E toggle switch on the front panel of the
Model 1093 and move it DOWN. This activates the V.52 BER
test mode and transmits a 511 pseudorandom test pattern to
the other unit. If any errors are received, the receiving Model
1093's red ER LED will blink sporadically.
NOTE: For this test to function, the 511 switch on both Model
1093's must be on.
2.
If the test indicates no errors are present, move the V.52
toggle switch UP, activating the 511/E test. The 511/E test
transmits the 511 pseudorandom test pattern and injects
intentional errors about once per second. If the test is work-
ing properly, the receiving Model 1093's red ER LED will blink
regularly .
A successful 511/E test will confirm that the link is in place,
and that the Model 1093 built-in 511 generator and detector
are working properly.
3.
This test can be done by one operator by first activating the
local analog loop or remote digital loop.
17
APPENDIX A
PATTON ELECTRONICS MODEL1093
SPECIFICATIONS
Transmission Format:
Synchronous
Transmission Line:
Unconditioned twisted pair 19 - 26 AWG
Clocking:
Internal, external or receive loopback
Distance:
Up to 6 miles (19 AWG @ 256 kbps)
Data Rates:
256 and 512 kbps (switch selectable)
Carrier Control:
Constantly on or Controlled by RTS
RTS/CTS Delay:
No delay, short delay (4 - 9 mSec), long
delay (33 - 71 mSec).
Diagnostics:
V.52 compliant bit error rate pattern
(511/511E pattern) generator and detector
with error injection mode; V.54
compliant—local analog loopback and
remote digital loopback, activated by front
panel switch or via serial interface
LED Indicators:
TD, RD, RTS, CD, DTR, ER and TM
(test mode)
Isolation:
Minimum 3000V RMS via transformers
Surge Protection:
Immune to IEC-801-5 Level 2, 1kV
Field-replaceable Quick Connect TM
DCE/DTE Interface:
modules.
Twisted Pair Interface:
8-position modular jack (RJ-45)
Power:
115/230 VAC (switch selectable), 50/60 Hz;
85 - 256 VAC, 50/60 Hz (universal input
option); 48 VDC (option). 5 watts.
Temperature Range:
0-50°C (32-122°F)
Altitude:
0-15,000 feet
Humidity:
5 to 95% non-condensing
Dimensions:
7.3" x 6.6" x 1.62"
(185mm x 168mm x 41mm)
Weight:
2.02 lbs. 1.0 Kg
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kilomodem-512 1093