APPENDIX B
PATTON MODEL 1002 CABLE RECOMMENDATIONS
The Patton Model 1002 operates at frequencies of 20kHz or less and
has been performance tested by Patton technicians using twisted-pair
cable with the following characteristics:
Wire Gauge
Capacitance
19 AWG/.9mm
83nf/mi or 15.72 pf/ft.
22 AWG/.6mm
83nf/mi or 15.72 pf/ft.
24 AWG/.5mm
83nf/mi or 15.72 pf/ft.
To gain optimum performance from the Model 1002, please keep the
following guidelines in mind:
• Always use twisted par wire—this is not an option.
• Use twisted pair wire with a capacitance of 20pf/ft or less.
• Avoid twisted pair wire thinner than 26 AWG (i.e. avoid higher
AWG numbers than 26)
• Use of twisted pair with a resistance greater than the above
specifications may cause a reduction in maximum distance
obtainable. Functionality should not be affected.
• Environmental factors too numerous to mention can affect the
maximum distances obtainable at a particular site. Use "maximum
distance" figures as a general guidelin only.
Model 1002 Distance Table in Miles (km)
Data Rate
(bps)
19 AWG
( 0.9 mm)
19,200
2.2(3.5)
9,600
3.0(4.8)
4,800
4.3(6.4)
2,400
5.3(8.5)
1,200
5.6(9.0)
11
Resistance
.0163 Ohms/ft.
.0326 Ohms/ft.
.05165 Ohms/ft.
Wire Gauge
24 AWG
26 AWG
(0.5 mm)
(0.4 mm)
1.6(2.6)
1.2(1.9)
2.1(3.4)
1.6(2.6)
2.6(4.2)
1.7(2.7)
2.8(4.5)
1.8(2.9)
2.8(4.5)
1.8(2.9)
APPENDIX C
PATTON MODEL 1002 INTERFACE CONNECTIONS
DIRECTION
STANDARD "DCE" SETTING
To Model 1002
Data Term. Ready (DTR) - 20
DIRECTION
STANDARD "DTE" SETTING
From Model 1002 Data Term. Ready (DTR) - 20
DIRECTION
1- (FG) Frame Ground
2- (TD) Transmit Data
To Model 1002
3- (RD) Receive Data
From Model 1002
4- (RTS) Request to Send
To Model 1002
5- (CTS) Clear to Send
From Model 1002
6- (DSR) Data Set Ready
From Model 1002
7- (SG) Signal Ground
8- (DCD) Data Carrier Detect
From Model 1002
DIRECTION
1- (FG) Frame Ground
2- (TD) Transmit Data
From Model 1002
3- (RD) Receive Data
To Model 1002
4- (RTS) Request to Send
From Model 1002
5- (CTS) Clear to Send
To Model 1002
6- (DSR) Data Set Ready
To Model 1002
7- (SG) Signal Ground
8- (DCD) Data Carrier Detect
To Model 1002
12

Advertisement

loading

This manual is also suitable for: