3.2 - MACHINE OPERATIONS AND OPERATING INSTRUCTIONS
LEV Model
Manual operations with lever operated coffee dispenser unit; thermostatically controlled heat exchanger in water heater maintains water at a constant
temperature. Available only for model Twenty.
B
A
MAX
L
MIN
P
A - Cup heater switch (optional)
B - Steam knob
C - Hot water knob
D - Water heater pressure gauge
Put the required amount of coffee into the filter holder and fit it under the unit. Next, lower the lever (T) relative to the unit used to dispense the coffee.
Similarly, you can stop dispensing the coffee by turning the lever (T) back up.
C
T
E
E - Main switch
F - Heating element pilot lamp
L - Boiler water level indicator (where applicable)