0.8 - TECHNICAL SPECIFICATIONS

TWENTY MODEL
Width
Depth
Height
Capacity
Supply voltage (Volt)
Absorbed power, resistance
Absorbed power, electric pump
Absorbed power, solenoid valve
Operating pressure, water heater
Set pressure, safety valve
Set pressure, heat exchanger safety
valve
Pressure, mains water supply(*)
Pressure, coffee dispensing
*
Use of a pressure reducer is recommended for values higher than those given.
(
)
L
Twenty Model
Units
1
2 c
2
3
°
n
mm
432
602
702
882
mm
600
mm
510
litri
4,9
4,9
10
15
110/230/400
V
kW
2,0
3,3
3,3
4,5
kW
0,165
kW
0,009
0,018
0,018
0,027
bar
0,9
bar
1,9
bar
12
bar
0÷4
bar
9÷10
600 mm
Units
4
3
2
°
n
1092
mm
850
660
mm
560
560
mm
520
520
20
litri
15
10
V
230/400
4,5
kW
4,5
3,3
kW
0,165
0,036
kW
0,027
0,018
bar
0,9
bar
1,9
bar
12
bar
0÷4
bar
9÷10
*
Use of a pressure reducer is recommended for values higher than those given.
(
)
L
G10 MODEL
Capacity
Supply voltage (Volt)
Absorbed power, resistance
Absorbed power, electric pump
Absorbed power, solenoid valve
Operating pressure, water heater
Set pressure, safety valve
Set pressure, heat exchanger safety
Pressure, mains water supply(*)
Pressure, coffee dispensing
560 mm
G10 Model
Width
Depth
Height
valve
35