Switching The Device On And Off - Waeco CombiPower 2012 Operating Manual

Sine wave inverter with integrated automatic charger
Table of Contents

Advertisement

Switching the device on and off

4.8
Connections
A battery is connected to the positive and negative terminals. A 230 V power
source can be connected to the "AC INPUT" input (fig. 1 6, page 3). The
power supply via "AC INPUT" takes precedence over the battery power
supply, so that the battery is not discharged unnecessarily.
Voltage is present at the outputs under the following conditions:
"INV. AC OUTPUT" (fig. 1 4, page 3)
– A battery is connected
– A 230 V power source is connected
– A battery and a 230 V power source are connected
(The battery is charged when the consumer devices do not require all
the power)
"AC OUTPUT" (fig. 1 5, page 3)
– A 230 V power source is connected
5
Switching the device on and off
NOTE
I
The main switch (fig. 1 10, page 3) on the device must be in the
"I" position.
➤ Press the "ON/OFF" button (fig. 3 2, page 4) on the remote control.
✓ The device is switched on and the message "System Initialisation ..."
appears in the display.
✓ After a few seconds, the display shows the message "System startup
please wait...".
The system status is checked.
✓ After 5 to 10 seconds, the display is ready and shows the status of the
device:
– The device is ready for use: the display shows operating parameters.
– Alarm messages are present: undervoltage, overload, fan failure,
overtemperature
– Faults have occurred: undervoltage (UVP), overvoltage (OVP), over-
temperature (OTP), overload (OLP)
48
CombiPower
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combipower 2024

Table of Contents