11.
Tap off the non drive end shield taking care not to damage
the wiring. Move the power cord out of its recess to a safe
position before proceeding to the next step.
13.
With a heat gun, heat this area turning the stator shell so
as not to blister the paint. After approximately 2 minutes
you should be able to tap out the rotor or push it out using
the bearing press.
15.
With the aid of the new bearing tool place the other
bearing on top and place the tool under the bearing press.
12.
Sealing Ring
O-ring
Slinger
To remove the rotor and perform a bearing change
remove the slinger, O-ring and the front sealing ring in
that order.
14.
Remove both bearings from the rotor but only replace the
non drive end bearing.
16.
Slide the stator and shell down over the bearing tool and
press it down until the bearing is seated correctly in the
stator shell.