SERVICE MANUAL TNC 151/155
Paae 51
Kundendienst
Se&ion
4.1
- The P.AMs -20.2-
on the main ~rocsssor
board con be accessed
b) TNC 151/155 Q-Versions:
either
by the main processor
-2O- or by the CLP processor.
The intended
coordinates,
programed
feed,
display
texts
etc.
can therefore
be transferred.
These RAMS also serve
as register
file
memory for
the main
processor
-2o-.
User programs,
machine parameters,
and (under certain
circm-
stances)
the PLC program are programed
in RAMS -20.4-.
- The 16-bit
address bus is extended
to 20-bit
by a memory
mapper 1.
- The keyboard
controller
-22- has the task of driving
the
LEDs and scanning
the keypads -22.1-
on the front
plate.
- The main processor
is connected
with V.24 interface
via
a
(serial)
CRU-bus. This interface
is used to exchange data by
means of a magnetic
taps unit
(ME) or, respectively,
an
external
processor.
- The PLC program contained
in IC-P9 -23.1-
is processed
by the
"1-bit-PLC-processor"
-23-
mounted discretely
on the main
processor
board.
The input
and output
states
are stored
in a
8k x 8 PLC-RAM -23.2-.
- I/O-Functions:
a) TNC X1/155
B-Versions:
24 galvanically
separated
inputs
(EO to E23) -5O- and 24
floating
relay
contact
outputs
(A0 to A22 + emergency stop)
-51- on the SE Board.
The inputs
and outputs
are protected
on the terminal
board
(B/F version)
by special
protective
resistances
5.lk*-70-
and 4F-70.1-.
Protective
resistances
should never
be replaced
with normal
resistances!
They are led via LC-filter
-71-
as protection
against
the
oscillation
of analog outputs.
The inputs
&d outputs
are loaded on an external
PLC
I/O-boards
(e.g.
PL 1OOB or,
respectively,
PL 100B)
which is driven
by the main processor
-2O- via
the PLC
interface
board.
The data is serially
transferred
via
the CRU-bus. All
lines
of this
bus as well
as the
required
addresses
ars galvanically
separated
by the
optocoupler
-5O- and are converted
from the TTL level
(5V) to the MOS level
(12V) by means of a level
converter
-51-.
Thus a higher
noise immunity
is obtained.
Under the control
of CRU addresses
63 programmable
inputs
(EO to E62) -E2- located
on the PLC I/O board are multi-
plexed
on CRUIN 1 line.
If
2 PLC I/O boards
are connected
the inputs
from the 2nd board are multiplexed
on CRUIN 2.
On the PLC interface
board either
CRUIN 1 or CRUIN 2 are
selected
-54- and are led to the main processor
via CRUIN.
The serial
CRUOUT signal
is converted
in 31 outputs
via
a
serial-parallel-converter
-El.l-.
The outputs
(each having
its
own current
supervision
-El-)
are transferred
via
line
drivers
to the machine interface.
- An overloaded
output
only switches
off
during
the period
of the overload.
- If the current
supervision
detects
overcurrent
no
emergency-stop
results
in the standard
PLC program.
The input
E63 is used to indicate
an overloaded
output
to
the main processor
-2O-.
PL 1008: 31 unipolar,
programmable
outputs
+
emergency-stops
protected
against
overload.
PL 1lOB: 26 unipolar,
programmable
outputs
+ 5 bipolar
outputs
protected
against
overload.
On the PLC I/O board a 12V voltage
is generated
by an
external
24V supply PIG I/O board.
On the PLC interface
board this
12V voltage
is transformed
in a 5V voltage
for
its
TTL modules.