SERVICE MANUAL TNC 151/155
Page 12
Section
2.2.2
VDD Display
(flashing)
PROCESSOR CHECK ERROR 0
I
1
2
3
A
B
C
D
E
F
G
H
I
J
K
L
Fault
cause
Incorrect
CRC checksum* of machine-related
data
excluding
machine parameters.
(Baud rate,
limitation,
preset
etc)
Incorrect
CRC checksum* (machine parameters)
Incorrect
CRC checksum* (user memory)
Integrated
Test Program execution
incomplete
Software
error
Main Processor
Software
error
CLP Processor
MID interrupt**
CLP Processor
CLP Processor
instruction
stack overflow
False instruction:
Main Processor
CLP Processor
False instruction
(display
mode): Main Processor
CLP Processor
CLP Processor
RAM
Overflow
interrupt
MID interrupt
Main Processor
Equipped with
incorrect
language
version
RAM EOOO . ..FFFF Main Processor
Enable a function
via machine parameters
which is
not integrated
in the software
Possible
fault
location
Main Processor
Board
Main Processor
Board
Main Processor
Board
Main Processor
Board
Main Processor
Board
CLP Processor/Graphics
Board
Main ProcessorjCLP
Processor/Graphics
Board
CLP Processor
Board
Main Processor/CLP
Processor/Graphics
Board
Main Processor/CLP
Processor/Graphics
Board
CLP Processor/Graphics
Board
Main Processor
Board
Main Processor
Board
Main Processor
Board
Main Processor
Board
False machine parameter
* CRC = Cyclic
Redundancy Check
** MID = Macro Instruction
Detection