Midea R410A T3 Top-discharge Split Type Series 50Hz
Step2: The value of the first code 'X' is '0', press the temperature setting buttons
Step3: After setting the second code value, press Quiet/OK button
Step4: When the first code value is '6', press Quiet/OK button
First
code
Cooling-only/Heat
0
selection
Indoor unit communication
1
address setting
2
Power-off memory
3
Filter cleaning reminding
5
Remote receiving function
Centigrade/Fahrenheit
6
display
Notes: The second code of the filter cleaning reminding is 2500hours, which as default.
135
to adjust the second code value.
code to the next value.
parameters setting.
The parameter setting table
Function
pump
0
Heat pump (Default)
Yes (Default)
Yes (Default)
Cancel the reminding
function
Yes (Default)
Centigrade (Default)
MCAC-UTSM-201501
to switch the first
again to exit the
Second code
1
2
Coolin
\
g only
None
\
None
\
1250
2500
5000
hours
hours
hours
None
\
Fahre
\
nheit
and
3
4
\
\
\
\
\
\
10000
hours
\
\
\
\